dc.identifier.citationElvas, L. B., Águas, P., Ferreira, J., Oliveira, J., Dias, J., & Rosário, L. B. (2023). AI-based aortic stenosis classification in MRI scans. Electronics, 12(23), 4835. https://dx.doi.org/10.3390/electronics12234835-
dc.identifier.issn2079-9292-
dc.identifier.urihttp://hdl.handle.net/10071/30821-
dc.description.abstractAortic stenosis (AS) is a critical cardiovascular condition that necessitates precise diagnosis for effective patient care. Despite a limited dataset comprising only 202 images, our study employs transfer learning to investigate the efficacy of five convolutional neural network (CNN) models, coupled with advanced computer vision techniques, in accurately classifying AS. The VGG16 model stands out among the tested models, achieving 95% recall and F1-score. To fortify the model’s robustness and generalization, we implement various data augmentation techniques, including translation, rotation, flip, and brightness adjustment. These techniques aim to capture real-world image variations encountered in clinical settings. Validation, conducted using authentic data from Hospital Santa Maria, not only affirms the clinical applicability of our model but also highlights the potential to develop robust models with a limited number of images. The models undergo training after the images undergo a series of computer vision and data augmentation techniques, as detailed in this paper. These techniques augment the size of our dataset, contributing to improved model performance. In conclusion, our study illuminates the potential of AI-driven AS detection in MRI scans. The integration of transfer learning, CNN models, and data augmentation yields high accuracy rates, even with a small dataset, as validated in real clinical cases.eng
dc.language.isoeng-
dc.publisherMDPI-
dc.relationinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04466%2F2020/PT-
dc.relationinfo:eu-repo/grantAgreement/FCT//UI%2FBD%2F151494%2F2021/PT-
dc.relationinfo:eu-repo/grantAgreement/FCT/3599-PPCDT/DSAIPA%2FAI%2F0122%2F2020/PT-
dc.rightsopenAccess-
dc.subjectMRI imagingeng
dc.subjectAortic disease classificationeng
dc.subjectAortic stenosiseng
dc.subjectArtificial intelligenceeng
dc.subjectDeep learningeng
dc.subjectMRI classificationeng
dc.subjectConvolutional neural networks (CNN)eng
dc.subjectTransfer learningeng
dc.subjectData augmentationeng
dc.titleAI-based aortic stenosis classification in MRI scanseng
dc.typearticle-
dc.peerreviewedyes-
dc.volume12-
dc.number23-
dc.date.updated2024-02-05T10:13:24Z-
dc.description.versioninfo:eu-repo/semantics/publishedVersion-
dc.identifier.doi10.3390/electronics12234835-
dc.subject.fosDomínio/Área Científica::Ciências Naturais::Ciências da Computação e da Informaçãopor
iscte.subject.odsIndústria, inovação e infraestruturaspor
iscte.identifier.cienciahttps://ciencia.iscte-iul.pt/id/ci-pub-99195-
iscte.alternateIdentifiers.wosWOS:001117960600001-
iscte.alternateIdentifiers.scopus2-s2.0-85179356063-
iscte.journalElectronics-
Aparece nas coleções:ISTAR-RI - Artigos em revistas científicas internacionais com arbitragem científica

Ficheiros deste registo:
Ficheiro TamanhoFormato 
article_99195.pdf3,91 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis Logotipo do Orcid 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.