Utilize este identificador para referenciar este registo:
http://hdl.handle.net/10071/35443Registo completo
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.contributor.author | Martins, R. A. | - |
| dc.contributor.author | Godinho, D. | - |
| dc.contributor.author | Felício, J. M. | - |
| dc.contributor.author | Savazzi, M. | - |
| dc.contributor.author | Costa, J. R. | - |
| dc.contributor.author | Conceição, R. | - |
| dc.contributor.author | Fernandes, C. A. | - |
| dc.date.accessioned | 2025-10-31T11:18:06Z | - |
| dc.date.issued | 2024 | - |
| dc.identifier.citation | - | |
| dc.identifier.isbn | 978-88-31299-09-1 | - |
| dc.identifier.uri | http://hdl.handle.net/10071/35443 | - |
| dc.description.abstract | In this paper, we indicate best practices that should be observed when using numerical solvers for microwave body sensing. We show the impact of not minding these aspects in the case of microwave breast scanning, using the Computer Simulation Technology software tool. To this end we simulate a homogeneous breast with a 5-mm radius spherical tumor placed inside. The breast is illuminated by a broadband antenna that operates in the 2-6 GHz band. The scattering parameters are then processed to reconstruct the reflectivity map of the breast. The results highlight that the conclusions drawn from simulations may be misleading or meaningless when the solver type or positioning of model elements (body and antennas) are not carefully applied. This is particularly critical when considering more complex scenarios, such as inhomogeneous or multilayer body models. | eng |
| dc.language.iso | eng | - |
| dc.publisher | IEEE | - |
| dc.relation | info:eu-repo/grantAgreement/FCT//SFRH%2FBD%2F144961%2F2019/PT | - |
| dc.relation | info:eu-repo/grantAgreement/FCT/Concurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017%2F2018) - Financiamento Base/UIDB%2F50008%2F2020/PT | - |
| dc.relation | info:eu-repo/grantAgreement/FCT/Concurso de avaliação no âmbito do Programa Plurianual de Financiamento de Unidades de I&D (2017%2F2018) - Financiamento Base/UIDB%2F00645%2F2020/PT | - |
| dc.relation.ispartof | 2024 18th European Conference on Antennas and Propagation (EuCAP) | - |
| dc.rights | openAccess | - |
| dc.subject | Microwave breast imaging | eng |
| dc.subject | Electromagnetic numerical solvers | eng |
| dc.subject | Broadband simulation | eng |
| dc.subject | Time-domain simulation | eng |
| dc.subject | Frequency-domain simulation | eng |
| dc.title | Best practices for accurate results using numerical solvers for microwave body screening | eng |
| dc.type | conferenceObject | - |
| dc.event.title | 18th European Conference on Antennas and Propagation (EuCAP) | - |
| dc.event.type | Conferência | pt |
| dc.event.location | Glasgow, United Kingdom | eng |
| dc.event.date | 2024 | - |
| dc.peerreviewed | yes | - |
| dc.date.updated | 2025-10-31T11:16:26Z | - |
| dc.description.version | info:eu-repo/semantics/acceptedVersion | - |
| dc.identifier.doi | 10.23919/EuCAP60739.2024.10501344 | - |
| dc.subject.fos | Domínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informática | por |
| dc.date.embargo | 2025-04-26 | - |
| iscte.subject.ods | Saúde de qualidade | por |
| iscte.subject.ods | Indústria, inovação e infraestruturas | por |
| iscte.identifier.ciencia | https://ciencia.iscte-iul.pt/id/ci-pub-112570 | - |
| iscte.alternateIdentifiers.wos | WOS:001215536202002 | - |
| iscte.alternateIdentifiers.scopus | 2-s2.0-85192462816 | - |
| Aparece nas coleções: | IT-CRI - Comunicações a conferências internacionais | |
Ficheiros deste registo:
| Ficheiro | Tamanho | Formato | |
|---|---|---|---|
| 1570965171 final.pdf | 953,34 kB | Adobe PDF | Ver/Abrir |
Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.












