Please use this identifier to cite or link to this item: http://hdl.handle.net/10071/30792
Author(s): Vala, M.
Felício, J. M.
Costa, T. S. da.
Leonor, N.
Costa, J. R.
Marques, P.
Moreira, A. A.
Matos, S. A.
Caldeirinha, R. F. S.
Fernandes, C. A.
Fonseca, N. J. G.
de Maagt, P.
Date: 2023
Title: On the feasibility of using Passive mm-Wave Imaging for marine litter detection at the w-band
Book title/volume: 2023 17th European Conference on Antennas and Propagation (EuCAP)
Event title: 17th European Conference on Antennas and Propagation (EuCAP)
Reference: Vala, M., Felício, J. M., Costa, T. S. da., Leonor, N., Costa, J. R., Marques, P., Moreira, A. A., Matos, S. A., Caldeirinha, R. F. S., Fernandes, C. A., Fonseca, N. J. G., & de Maagt, P. (2023). On the feasibility of using Passive mm-Wave Imaging for marine litter detection at the w-band. 2023 17th European Conference on Antennas and Propagation (EuCAP). IEEE. https://doi.org/10.23919/EuCAP57121.2023.10133069
ISBN: 978-1-6654-7541-9
DOI (Digital Object Identifier): 10.23919/EuCAP57121.2023.10133069
Keywords: Marine plastics
PMMW
Passive radar
Radiometer
W-band
Abstract: Large research effort is appearing in the literature on remote detection of plastic marine litter, using optical instruments, and lately microwaves. We present here a feasibility study of passive mm-wave imaging (PMMWI) for the same goal. Several measurements were taken in a controlled pool environment both in static and agitated water conditions using a W-band radiometer to assess the influence of plastic on the radiometric response. Different sized plastic bottles and concentrations were studied to verify its influence on the results provided by the radiometer. For each measurement, references of still water were taken to correct eventual errors due to equipment drifts in terms of gain and noise. Preliminary results show that it is possible to detect differences in the radiometers output voltage when plastic is present or the water is agitated or both and, thus, PMMW imaging seems to be a promising technology for remote detection of floating plastics.
Peerreviewed: yes
Access type: Embargoed Access
Appears in Collections:IT-CRI - Comunicações a conferências internacionais

Files in This Item:
File SizeFormat 
conferenceobject_97411.pdf
  Restricted Access
5,31 MBAdobe PDFView/Open Request a copy


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpaceOrkut
Formato BibTex mendeley Endnote Logotipo do DeGóis Logotipo do Orcid 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.