Artificial intelligence as a transforming factor in motility disorders–automatic detection of motility patterns in high-resolution anorectal manometry

dc.contributor.authorMascarenhas, M.
dc.contributor.authorMendes, F.
dc.contributor.authorMota, J.
dc.contributor.authorRibeiro, T.
dc.contributor.authorCardoso, P.
dc.contributor.authorMartins, M.
dc.contributor.authorAlmeida, M. J.
dc.contributor.authorCordeiro, J. R.
dc.contributor.authorFerreira, J.
dc.contributor.authorMacedo, G.
dc.contributor.authorSantander, C.
dc.date.accessioned2025-04-09T09:40:26Z
dc.date.available2025-04-09T09:40:26Z
dc.date.issued2025
dc.date.updated2025-04-09T10:38:16Z
dc.description.abstractHigh-resolution anorectal manometry (HR-ARM) is the gold standard for anorectal functional disorders’ evaluation, despite being limited by its accessibility and complex data analysis. The London Protocol and Classification were developed to standardize anorectal motility patterns classification. This proof-of-concept study aims to develop and validate an artificial intelligence model for identification and differentiation of disorders of anal tone and contractility in HR-ARM. A dataset of 701 HR-ARM exams from a tertiary center, classified according to London Classification, was used to develop and test multiple machine learning (ML) algorithms. The exams were divided in a training and testing dataset with a 80/20% ratio. The testing dataset was used for models’ evaluation through its accuracy, sensitivity, specificity, positive and negative predictive values and area under the receiving-operating characteristic curve. LGBM Classifier had the best performance, with an accuracy of 87.0% for identifying disorders of anal tone and contractility. Different ML models excelled in distinguishing specific disorders of anal tone and contractility, with accuracy over 90.0%. This is the first worldwide study proving the accuracy of a ML model for differentiation of motility patterns in HR-ARM, demonstrating the value of artificial intelligence models in optimizing HR-ARM availability while reducing interobserver variability and increasing accuracy.eng
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationMascarenhas, M., Mendes, F., Mota, J., Ribeiro, T., Cardoso, P., Martins, M., Almeida, M. J., Cordeiro, J. R., Ferreira, J., Macedo, G., & Santander, C. (2025). Artificial intelligence as a transforming factor in motility disorders–automatic detection of motility patterns in high-resolution anorectal manometry. Scientific Reports, 15(1), Article 2061. https://doi.org/10.1038/s41598-024-83768-8
dc.identifier.doi10.1038/s41598-024-83768-8
dc.identifier.issn2045-2322
dc.identifier.urihttp://hdl.handle.net/10071/34185
dc.language.isoeng
dc.number1
dc.peerreviewedyes
dc.publisherNature Publishing Group
dc.rightsopen access
dc.subjectAnorectal disorderseng
dc.subjectAnorectal manometryeng
dc.subjectArtificial intelligenceeng
dc.subjectGastroenterologyeng
dc.subjectMachine learningeng
dc.subject.fosDomínio/Área Científica::Ciências Naturais::Outras Ciências Naturaispor
dc.titleArtificial intelligence as a transforming factor in motility disorders–automatic detection of motility patterns in high-resolution anorectal manometryeng
dc.typearticle
dc.volume15
dspace.entity.typePublicationen
iscte.alternateIdentifiers.scopus2-s2.0-85215962992
iscte.alternateIdentifiers.wosWOS:WOS:001398126400044
iscte.identifier.cienciahttps://ciencia.iscte-iul.pt/id/ci-pub-110600
iscte.journalScientific Reports

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
article_110600.pdf
Tamanho:
2.92 MB
Formato:
Adobe Portable Document Format
Descrição:
Versão Editora