Development of an anthropomorphic phantom of the axillary region for microwave imaging assessment

dc.contributor.authorSavazzi, M.
dc.contributor.authorAbedi, S.
dc.contributor.authorIštuk, N.
dc.contributor.authorJoachimowicz, N.
dc.contributor.authorRoussel, H.
dc.contributor.authorPorter, E.
dc.contributor.authorO’Halloran, M.
dc.contributor.authorCosta, J. R.
dc.contributor.authorFernandes, C. A.
dc.contributor.authorFelício, J. M.
dc.contributor.authorConceição, R. C.
dc.date.accessioned2021-01-04T12:14:25Z
dc.date.available2021-01-04T12:14:25Z
dc.date.issued2020
dc.date.updated2021-01-04T12:10:16Z
dc.description.abstractWe produced an anatomically and dielectrically realistic phantom of the axillary region to enable the experimental assessment of Axillary Lymph Node (ALN) imaging using microwave imaging technology. We segmented a thoracic Computed Tomography (CT) scan and created a computer-aided designed file containing the anatomical configuration of the axillary region. The phantom comprises five 3D-printed parts representing the main tissues of interest of the axillary region for the purpose of microwave imaging: fat, muscle, bone, ALNs, and lung. The phantom allows the experimental assessment of multiple anatomical configurations, by including ALNs of different size, shape, and number in several locations. Except for the bone mimicking organ, which is made of solid conductive polymer, we 3D-printed cavities to represent the fat, muscle, ALN, and lung and filled them with appropriate tissue-mimicking liquids. Existing studies about complex permittivity of ALNs have reported limitations. To address these, we measured the complex permittivity of both human and animal lymph nodes using the standard open-ended coaxial-probe technique, over the 0.5 GHz–8.5 GHz frequency band, thus extending current knowledge on dielectric properties of ALNs. Lastly, we numerically evaluated the effect of the polymer which constitutes the cavities of the phantom and compared it to the realistic axillary region. The results showed a maximum difference of 7 dB at 4 GHz in the electric field magnitude coupled to the tissues and a maximum of 10 dB difference in the ALN response. Our results showed that the phantom is a good representation of the axillary region and a viable tool for pre-clinical assessment of microwave imaging technology.eng
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.doi10.3390/s20174968
dc.identifier.issn1424-3210
dc.identifier.urihttp://hdl.handle.net/10071/21059
dc.journalSensors
dc.language.isoeng
dc.number17
dc.peerreviewedyes
dc.publisherMDPI
dc.relation764479
dc.relationUIDB/00645/2020
dc.relationUIDB/EEA/50008/2020
dc.rightsopen access
dc.subjectAnthropomorphic phantomeng
dc.subjectAxillary lymph node diagnosiseng
dc.subjectBiological tissue dielectric propertieseng
dc.subjectBreast cancereng
dc.subjectMicrowave imagingeng
dc.subjectOpen-ended coaxial-probeeng
dc.subjectPre-clinical testingeng
dc.subject.fosDomínio/Área Científica::Engenharia e Tecnologia::Engenharia Eletrotécnica, Eletrónica e Informáticapor
dc.titleDevelopment of an anthropomorphic phantom of the axillary region for microwave imaging assessmenteng
dc.typearticle
dc.volume20
degois.publication.issue17
degois.publication.titleDevelopment of an anthropomorphic phantom of the axillary region for microwave imaging assessmenteng
dspace.entity.typePublicationen
iscte.alternateIdentifiers.scopus2-s2.0-85090095610
iscte.alternateIdentifiers.wosWOS:000569667200001
iscte.identifier.cienciahttps://ciencia.iscte-iul.pt/id/ci-pub-74195
iscte.subject.odsSaúde de qualidadepor
iscte.subject.odsEducação de qualidadepor

Ficheiros

Pacote original

A mostrar 1 - 1 de 1
A carregar...
Nome:
Sensors_20.pdf
Tamanho:
6.93 MB
Formato:
Adobe Portable Document Format
Descrição:
Versão Editora