Contactless Impedance Cardiography Using Embedded Sensors

dc.contributor.authorPinheiro, E.
dc.contributor.authorPostolache, O.
dc.contributor.authorGirão, P.
dc.date.accessioned2014-05-22T11:16:32Z
dc.date.available2014-05-22T11:16:32Z
dc.date.issued2013
dc.date.updated2014-05-22T11:15:03Z
dc.descriptionWOS:000322540700008 (Nº de Acesso Web of Science)
dc.description.abstractImpedance cardiography is a technique developed with the intent of monitoring cardiac output. By inspecting a few properties of the obtained signal (impedance cardiogram (ICG), the left ventricular ejection time can be derived with certainty, and an estimate of cardiac output is available. This signal is nowadays used in non-invasive monitoring, requiring the placement of electrodes over the subject’s skin, either ECG-type or in the form of encircling bands. The work here reported describes the implementation steps and the results obtained when embedding the ICG circuitry in a wheelchair’s backrest. The subject is seated normally, is normally dressed, and is completely unaware that monitoring is taking place. That means that the variation of tenths of ohm produced due to the cardiac cycle has to be detected with electrodes having substantial coupling impedance. Contactless ICG with embedded sensors was developed and tested on fourteen healthy subjects. The signal was always acquired, although respiratory activity is also important, constituting a noteworthy innovation in the areapor
dc.distributionInternacionalpor
dc.identifierhttp://dx.doi.org/10.2478/msr-2013-0025en_US
dc.identifier.issn1335-8871por
dc.identifier.urihttp://www.degruyter.com/view/j/msr.2013.13.issue-3/msr-2013-0025/msr-2013-0025.xmlen_US
dc.identifier.urihttps://ciencia.iscte-iul.pt/public/pub/id/15039en_US
dc.identifier.urihttp://hdl.handle.net/10071/7333
dc.journalMeasurement Science Reviewpor
dc.language.isoengpor
dc.number3por
dc.pagination157-164por
dc.peerreviewedSimpor
dc.publicationstatusPublicadopor
dc.publisherInstitute of Measurement Science. Slovak Academypor
dc.relation.publisherversionThe definitive version is available at: http://dx.doi.org/10.2478/msr-2013-0025por
dc.rightsembargoed accesspor
dc.subjectBiomedical instrumentationpor
dc.subjectEmbedded sensingpor
dc.subjectImpedance measurementpor
dc.subjectNon-invasive monitoringpor
dc.subjectUnobtrusive devicespor
dc.subjectWheelchair technologypor
dc.titleContactless Impedance Cardiography Using Embedded Sensorspor
dc.typearticleen_US
dc.volume13por
degois.publication.firstPage157por
degois.publication.issue3por
degois.publication.lastPage164por
degois.publication.titleMeasurement Science Reviewpor
dspace.entity.typePublicationen

Ficheiros